Manual DescriptionPrecaution for Technicians Using Medical Electric 4, point to Be Checked Before Starting Maintenance, (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER" 4, precaution for Procedure without Cowl Top Cover 5.
Precautions for Removing Battery Terminal 8, location of Traction Motor Model Number and Serial Number Stamps 11, tRACTION MOTOR INVERTER : System Description17, mOTOR POWER CONTROL : System Description19.
MOTOR POWER CONTROL : Operating Principle19, mOTOR REGENERATION CONTROL : Operating Principle20, dIAGNOSIS DESCRIPTION : DTC Freeze, dIAGNOSIS AND REPAIR WORK FLOW 36.
DRIVE MOTOR A CONTROL MODULE 41, dRIVE MOTOR A TEMP SENSOR 42, component Inspection (Traction Motor Temperature Sensor) 43, dRIVE MOTOR A TEMP SENSOR 44.
Component Inspection (Traction Motor Temperature Sensor) 45, dRIVE MOTOR A OVER TEMPERATURE 46, component Inspection (Traction Motor Temperature Sensor) 48, dRIVE MOTOR A POSITION SENSOR 50.
Component Inspection (Traction Motor Resolver) 51, d-MOTOR A PHASE U CURRENT, d-MOTOR A PHASE V CURRENT, dRIVE MOTOR A INVERTER VOLTAGE 62.
DRIVE MOTOR A OVER SPEED 53, component Inspection (Traction Motor Resolver) 54, dRIVE MOTOR A INVERTER 56, dRIVE MOTOR A INVERTER CRNT.
DRIVE MOTOR A INVERTER 92, dRIVE MOTOR A POSITION 93, dRIVE MOTOR A POSITION 94 TMS, dRIVE MOTOR A POSITION 95.
DRIVE MOTOR A POSITION 96, tRACTION MOTOR INSULATION RESISTANCE CHECK 98, dRIVE MOTOR A INVERTER VOLTAGE85, tRACTION MOTOR INVERTER INSULATION RESISTANCE CHECK 100.
DRIVE MOTOR A INVERTER IGBT87, dRIVE MOTOR A INVERTER IGBT90, precaution for Technicians Using Medical Electric, parts with strong magnet is used vehicle.
Technicians using a medical electric device such as pacemaker must never perform operation, vehicle, as magnetic field can affect the device function by approaching such parts, if a technician uses a medical electric device such as an implantable cardiac pacemaker an, implantable cardioverter defibrillator, the possible effects on the devices must be checked with.
Device manufacturer before starting charge operation, as radiated electromagnetic wave generated by PDM (Power Delivery Module) normal charge, operation may affect medical electric devices, a technician using a medical electric device such, implantable cardiac pacemaker or an implantable cardioverter defibrillator must not approach motor.
Room [PDM (Power Delivery Module)] at the hood-opened condition during normal charge operation, if a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), avoid the device implanted part from approaching within approximately 220 mm (8, the electromagnetic wave of TCU might affect the function of the implantable cardiac pacemaker.
The implantable cardioverter defibrillator (ICD), when using service, etc, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of TCU might affect function, pRECAUTION AT INTELLIGENT KEY SYSTEM OPERATION.