Download Brake System (Section BR)
Manual DescriptionDIAGNOSIS SYSTEM (ELECTRICALLYDRIVEN INTELLIGENT BRAKE UNIT) 29, precaution for Technicians Using Medical Electric 5, point to Be Checked Before Starting Maintenance, (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER" 5.
Precaution for Removing 12V Battery 6, precaution for Procedure without Cowl Top Cover 6, brake Power Supply Backup Unit 13, dIAGNOSIS AND REPAIR WORK FLOW 49.
Hill start assist FUNCTION : System Description 22, sTROKE SENSOR POINT LEARNING 53, pOWER SUPPLY AND GROUND CIRCUIT 470, tHE BRAKING DISTANCE IS LONG 480.
BRAKE PAD : Inspection Adjustment496, dISC ROTOR : Inspection Adjustment496, bRAKE PAD : Exploded View 516, bRAKE PAD : Removal Installation 516.
BRAKE CALIPER ASSEMBLY : Exploded View, bRAKE CALIPER ASSEMBLY : Removal Installation 518, bRAKE CALIPER ASSEMBLY : Disassembly, bRAKE CALIPER ASSEMBLY : Inspection 521.
BRAKE PAD : Exploded View 522, bRAKE PAD : Removal Installation 522, bRAKE PAD : Inspection Adjustment498, dISC ROTOR : Inspection Adjustment498.
BRAKE POWER SUPPLY BACKUP UNIT 513, bRAKE CALIPER ASSEMBLY : Removal Installation 526, bRAKE CALIPER ASSEMBLY : Inspection 529, precaution for Technicians Using Medical Electric.
Parts with strong magnet is used vehicle, technicians using a medical electric device such as pacemaker must never perform operation, vehicle, as magnetic field can affect the device function by approaching such parts, if a technician uses a medical electric device such as an implantable cardiac pacemaker an E.
Implantable cardioverter defibrillator, the possible effects on the devices must be checked with, device manufacturer before starting charge operation, as radiated electromagnetic wave generated by PDM (Power Delivery Module) normal charge, operation may affect medical electric devices, a technician using a medical electric device such.
Implantable cardiac pacemaker or an implantable cardioverter defibrillator must not approach motor, room [PDM (Power Delivery Module)] at the hood-opened condition during normal charge operation, if a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), avoid the device implanted part from approaching within approximately 220 mm (8.
The electromagnetic wave of TCU might affect the function of the implantable cardiac pacemaker, the implantable cardioverter defibrillator (ICD), when using service, etc, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of TCU might affect function, pRECAUTION AT INTELLIGENT KEY SYSTEM OPERATION.
The electromagnetic wave of Intelligent Key might affect the function implantable cardiac, pacemaker or the implantable cardioverter defibrillator (ICD), at door operation, each request, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of Intelligent Key might affect, point to Be Checked Before Starting Maintenance Work.
Precaution for Supplemental Restraint System (SRS) "AIR BAG" "SEAT BELT, the Supplemental Restraint System such as AIR BAG” and SEAT BELT PRE-TENSIONER”, used along, with a front seat belt, helps to reduce the risk or severity of injury to the driver and front passenger certain, the high voltage system may starts automatically.
And timer charge (during EVSE connection) are not set before starting maintenance work, if the timer air conditioner or timer charge (during EVSE connection) is set, the high voltage system starts, automatically even when the power switch OFF state.