Download Vihicle Charging System (VC)
Manual DescriptionPrecaution for Technicians Using Medical Electric 4, point to Be Checked Before Starting Maintenance, (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER" 4, precaution for Procedure without Cowl Top Cover 5.
Precautions for Removing Battery Terminal 5, cHARGE PORT CONTROL : System Description 19, pOWER VOLTAGE VARIABLE CONTROL SYSTEM : System Description22, aUTOMATIC BATTERY CHARGE CONTROL : System Description22.
LI-ION BATTERY CHARGE CONTROL : System, oN BOARD DIAGNOSTIC (OBD) SYSTEM 27, dIAGNOSIS SYSTEM [PDM(POWER DELIVERY MODULE)] 28, vEHICLE CHARGING SYSTEM : System Description 17.
DIAGNOSIS AND REPAIR WORK FLOW 54, pOWER SUPPLY AND GROUND CIRCUIT 61, pDM (POWER DELIVERY MODULE) : Diagnosis, qUICK CHARGE VOLTAGE SENSOR 81.
TYPE C : Diagnosis Procedure 86, tYPE A : Diagnosis Procedure 69, tYPE B : Diagnosis Procedure 71, tYPE A : Diagnosis Procedure 88.
TYPE B : Diagnosis Procedure 90, tYPE B : Diagnosis Procedure 93, tYPE C : Diagnosis Procedure 94, tYPE D : Diagnosis Procedure 94.
TYPE A : Diagnosis Procedure 100, tYPE B : Diagnosis Procedure 102, precaution for Technicians Using Medical Electric, parts with strong magnet is used vehicle.
Technicians using a medical electric device such as pacemaker must never perform operation, vehicle, as magnetic field can affect the device function by approaching such parts, if a technician uses a medical electric device such as an implantable cardiac pacemaker an, implantable cardioverter defibrillator, the possible effects on the devices must be checked with.
Device manufacturer before starting charge operation, as radiated electromagnetic wave generated by PDM (Power Delivery Module) normal charge, operation may affect medical electric devices, a technician using a medical electric device such, implantable cardiac pacemaker or an implantable cardioverter defibrillator must not approach motor.
Room [PDM (Power Delivery Module)] at the hood-opened condition during normal charge operation, if a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), avoid the device implanted part from approaching within approximately 220 mm (8, the electromagnetic wave of TCU might affect the function of the implantable cardiac pacemaker.
The implantable cardioverter defibrillator (ICD), when using service, etc, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of TCU might affect function, pRECAUTION AT INTELLIGENT KEY SYSTEM OPERATION, the electromagnetic wave of Intelligent Key might affect the function implantable cardiac.
Pacemaker or the implantable cardioverter defibrillator (ICD), at door operation, each request, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of Intelligent Key might affect, point to Be Checked Before Starting Maintenance Work, the high voltage system may starts automatically.
And timer charge (during EVSE connection) are not set before starting maintenance work, if the timer air conditioner or timer charge (during EVSE connection) is set, the high voltage system starts, automatically even when the power switch OFF state, precaution for Supplemental Restraint System (SRS) "AIR BAG" "SEAT BELT.
The Supplemental Restraint System such as AIR BAG” and SEAT BELT PRE-TENSIONER”, used along, with a front seat belt, helps to reduce the risk or severity of injury to the driver and front passenger certain, system uses the seat belt switches to determine the front air bag deployment, and may only deploy one front.