2013 Nissan Leaf - Heater & Air Condition (Section HA) (119 pages)

Model: 2013 Nissan Leaf
File size: 4.03 MB
Pages: 119 pages



Download Heater & Air Condition (Section HA)

Manual Description
Precaution for Technicians Using Medical Electric 4, point to Be Checked Before Starting Maintenance, (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER" 4, precaution for Procedure without Cowl Top Cover 5.

Precaution for Removing 12V Battery 7, precautions for Service Work Cooler System 8, dIAGNOSIS AND REPAIR WORK FLOW 24, hEATING AND COOLING UNIT ASSEMBLY 16.

HEATING AND COOLING UNIT ASSEMBLY , hEATING AND COOLING UNIT ASSEMBLY : Inner condenser 16, hIGH-PRESSURE PIPE : Removal Installation 46, vALVE AND 3-WAY VALVE ASSEMBLY 47.

VALVE AND 3-WAY VALVE ASSEMBLY, aCCUMULATOR ASSEMBLY : Removal Installation 50, hEATING AND COOLING UNIT ASSEMBLY 55, hEATING AND COOLING UNIT ASSEMBLY 57.

EVAPORATOR : Removal Installation 60, iNNER CONDENSER : Removal Installation 61, precaution for Technicians Using Medical Electric 63, (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER" 63.

Precaution for Procedure without Cowl Top Cover 64, precaution for Removing 12V Battery 66, precautions for Service Work Cooler System 67, hEATING AND COOLING UNIT ASSEMBLY 74.

Heating and Cooling Unit Assembly 75, rEFRIGERATION SYSTEM : System Diagram 80, dIAGNOSIS AND REPAIR WORK FLOW 82, perform Lubricant Return Operation 87.

Trouble Diagnosis For Unusual Pressure 92, lOW-PRESSURE PIPE : Removal Installation 105, cONDENSER : Removal Installation 107, lIQUID TANK : Removal Installation 110.

REFRIGERANT PRESSURE SENSOR : Removal Installation 111, hEATING AND COOLING UNIT ASSEMBLY 114, eVAPORATOR : Removal Installation 117, eXPANSION VALVE : Removal Installation 117.

HIGH-PRESSURE PIPE : Removal Installation 104, precaution for Technicians Using Medical Electric, parts with strong magnet is used vehicle, technicians using a medical electric device such as pacemaker must never perform operation.

Vehicle, as magnetic field can affect the device function by approaching such parts, if a technician uses a medical electric device such as an implantable cardiac pacemaker an, implantable cardioverter defibrillator, the possible effects on the devices must be checked with, device manufacturer before starting charge operation.

As radiated electromagnetic wave generated by PDM (Power Delivery Module) normal charge, operation may affect medical electric devices, a technician using a medical electric device such, implantable cardiac pacemaker or an implantable cardioverter defibrillator must not approach motor, room [PDM (Power Delivery Module)] at the hood-opened condition during normal charge operation.

If a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), avoid the device implanted part from approaching within approximately 220 mm (8, the electromagnetic wave of TCU might affect the function of the implantable cardiac pacemaker, the implantable cardioverter defibrillator (ICD), when using service, etc.

If a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of TCU might affect function, pRECAUTION AT INTELLIGENT KEY SYSTEM OPERATION, the electromagnetic wave of Intelligent Key might affect the function implantable cardiac.