Download Brake System (Section BR)
Manual DescriptionHOW TO USE THIS MANUAL 5, how to Check Vehicle Type 5, precaution for Technicians Using Medical Electric 6, point to Be Checked Before Starting Maintenance.
(SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER" 6, precaution for Removing 12V Battery 7, precaution for Procedure without Cowl Top Cover 7, hill start assist FUNCTION : System Description26.
DIAGNOSIS SYSTEM (ELECTRICALLYDRIVEN INTELLIGENT BRAKE UNIT) 35, front Door Switch (Driver side) 14, brake Power Supply Backup Unit 14, dIAGNOSIS AND REPAIR WORK FLOW 72.
STROKE SENSOR POINT LEARNING 76, pOWER SUPPLY AND GROUND CIRCUIT 493, tHE BRAKING DISTANCE IS LONG 504, bRAKE POWER SUPPLY BACKUP UNIT 536.
BRAKE PAD : Inspection Adjustment519, dISC ROTOR : Inspection Adjustment519, bRAKE PAD : Inspection Adjustment521, dISC ROTOR : Inspection Adjustment521.
BRAKE PAD : Exploded View 539, bRAKE PAD : Removal Installation 539, bRAKE CALIPER ASSEMBLY : Exploded View, bRAKE CALIPER ASSEMBLY : Removal Installation 543.
BRAKE CALIPER ASSEMBLY : Disassembly, bRAKE CALIPER ASSEMBLY : Inspection 546, bRAKE PAD : Exploded View 547, bRAKE PAD : Removal Installation 547.
BRAKE CALIPER ASSEMBLY : Removal Installation 551, bRAKE CALIPER ASSEMBLY : Inspection 554, check the vehicle type (refer to GI-23, "Model Variation") to confirm the service information BR section, precaution for Technicians Using Medical Electric.
Parts with strong magnet is used vehicle, technicians using a medical electric device such as pacemaker must never perform operation, vehicle, as magnetic field can affect the device function by approaching such parts, if a technician uses a medical electric device such as an implantable cardiac pacemaker an.
Implantable cardioverter defibrillator, the possible effects on the devices must be checked with, device manufacturer before starting charge operation, as radiated electromagnetic wave generated by PDM (Power Delivery Module) normal charge, operation may affect medical electric devices, a technician using a medical electric device such.
Implantable cardiac pacemaker or an implantable cardioverter defibrillator must not approach motor, room [PDM (Power Delivery Module)] at the hood-opened condition during normal charge operation, if a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), avoid the device implanted part from approaching within approximately 220 mm (8.
The electromagnetic wave of TCU might affect the function of the implantable cardiac pacemaker, the implantable cardioverter defibrillator (ICD), when using service, etc, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of TCU might affect function, pRECAUTION AT INTELLIGENT KEY SYSTEM OPERATION.
The electromagnetic wave of Intelligent Key might affect the function implantable cardiac, pacemaker or the implantable cardioverter defibrillator (ICD), at door operation, each request, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of Intelligent Key might affect, point to Be Checked Before Starting Maintenance Work.
The high voltage system may starts automatically, and timer charge (during EVSE connection) are not set before starting maintenance work, if the timer air conditioner or timer charge (during EVSE connection) is set, the high voltage system starts.