2012 Nissan Leaf - Wiper Washer (Section WW) (61 pages)

Model: 2012 Nissan Leaf
File size: 1.24 MB
Pages: 61 pages



Download Wiper Washer (Section WW)

Manual Description
Precaution for Technicians Using Medical Electric 3, point to Be Checked Before Starting Maintenance, (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER" 3, precaution for Procedure without Cowl Top Cover 4.

Precautions for Removing Battery Terminal 4, cOMMON ITEM : CONSULT Function (BCM COMMON ITEM)17, wIPER : CONSULT Function - WIPER19, dIAGNOSIS AND REPAIR WORK FLOW 26.

FRONT WIPER AND WASHER SYSTEM 9, fRONT WIPER AND WASHER SYSTEM : System Description 9, fRONT WIPER AND WASHER SYSTEM : Circuit, fRONT WIPER AND WASHER SYSTEM : Failsafe 12.

REAR WIPER AND WASHER SYSTEM 13, rEAR WIPER AND WASHER SYSTEM : System, rEAR WIPER AND WASHER SYSTEM : Circuit, rEAR WIPER AND WASHER SYSTEM : Failsafe 15.

FRONT WIPER MOTOR LO CIRCUIT 30, fRONT WIPER MOTOR HI CIRCUIT 31, fRONT WIPER MOTOR GROUND CIRCUIT 33, fRONT WASHER NOZZLE AND TUBE 46.

REAR WIPER STOP POSITION SIGNAL CIRCUIT 37, fRONT WIPER DOES NOT OPERATE 41, rEAR WASHER NOZZLE AND TUBE 59, precaution for Technicians Using Medical Electric.

Parts with strong magnet is used vehicle, technicians using a medical electric device such as pacemaker must never perform operation, vehicle, as magnetic field can affect the device function by approaching such parts, if a technician uses a medical electric device such as an implantable cardiac pacemaker an.

Implantable cardioverter defibrillator, the possible effects on the devices must be checked with, device manufacturer before starting charge operation, as radiated electromagnetic wave generated by on board charger at normal charge operation may, effect medical electric devices, a technician using a medical electric device such as implantable cardiac pacemaker or an implantable cardioverter defibrillator must not enter vehicle compartment.

(including luggage room) during normal charge operation, if a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), avoid the device implanted part from approaching within approximately 220 mm (8, the electromagnetic wave of TCU might affect the function of the implantable cardiac pacemaker.

The implantable cardioverter defibrillator (ICD), when using service, etc, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of TCU might affect function, pRECAUTION AT INTELLIGENT KEY SYSTEM OPERATION, the electromagnetic wave of Intelligent Key might affect the function implantable cardiac.

Pacemaker or the implantable cardioverter defibrillator (ICD), at door operation, each request, if a technician uses other medical electric devices than implantable cardiac pacemaker implant- M, able cardioverter defibrillator (ICD), the electromagnetic wave of Intelligent Key might affect, point to Be Checked Before Starting Maintenance Work.

The high voltage system may starts automatically, and timer charge (during EVSE connection) are not set before starting maintenance work, if the timer air conditioner or timer charge (during EVSE connection) is set, the high voltage system starts, automatically even when the power switch OFF state.

Precaution for Supplemental Restraint System (SRS) "AIR BAG" "SEAT BELT, the Supplemental Restraint System such as AIR BAG” and SEAT BELT PRE-TENSIONER”, used along, with a front seat belt, helps to reduce the risk or severity of injury to the driver and front passenger certain, system uses the seat belt switches to determine the front air bag deployment, and may only deploy one front.

Air bag, depending on the severity of a collision and whether the front occupants belted unbelted, information necessary to service the system safely is included in the SRS AIR BAG” and SEAT BELT”, always observe the following items preventing accidental activation.