Download Meter, Warning Lamp & Indicator (Section MWI)
Manual DescriptionPrecaution for Technicians Using Medical Electric 3, point to Be Checked Before Starting Maintenance, (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER" 3, precautions for Removing Battery Terminal 4.
METER SYSTEM : Component Parts Location 7, mETER SYSTEM : Upper Meter 7, mETER SYSTEM : Combination Meter 7, mETER SYSTEM : Meter Control Switch 8.
METER SYSTEM : System Description 9, mETER SYSTEM : Circuit Diagram 17, pOWER METER : System Description 19, lI-ION BATTERY CAPACITY LEVEL GAUGE 22.
LI-ION BATTERY CAPACITY LEVEL GAUGE , dRIVING RANGE DISPLAY : System Description 30, oUTSIDE AIR TEMPERATURE DISPLAY : System Description31, mASTER WARNING LAMP : System Description 33.
METER ILLUMINATION CONTROL : System Description35, mETER EFFECT FUNCTION : System Description36, mETER CONTROL SWITCH SIGNAL CIRCUIT 87, wASHER LEVEL SWITCH SIGNAL CIRCUIT 89.
THE METER CONTROL SWITCH IS INOPERATIVE 90, pOWER SUPPLY AND GROUND CIRCUIT 83, cOMBINATION METER : Diagnosis Procedure 83, uPPER METER : Diagnosis Procedure 83.
DISPLAYING, OR DOES NOT DISPLAY 91, uPPER METER DOES NOT OPERATE 92, tHE OUTSIDE AIR TEMPERATURE DISPLAY IS INCORRECT 93, tHE LOW WASHER FLUID WARNING CONTINUES DISPLAYING, or DOES NOT DISPLAY 94.
Precaution for Technicians Using Medical Electric, parts with strong magnet is used vehicle, technicians using a medical electric device such as pacemaker must never perform operation, vehicle, as magnetic field can affect the device function by approaching such parts.
If a technician uses a medical electric device such as an implantable cardiac pacemaker an, implantable cardioverter defibrillator, the possible effects on the devices must be checked with, device manufacturer before starting charge operation, as radiated electromagnetic wave generated by on board charger at normal charge operation may.
Effect medical electric devices, a technician using a medical electric device such as implantable cardiac pacemaker or an implantable cardioverter defibrillator must not enter vehicle compartment, (including luggage room) during normal charge operation, if a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), avoid the device implanted part from approaching within approximately 220 mm (8.
The electromagnetic wave of TCU might affect the function of the implantable cardiac pacemaker, the implantable cardioverter defibrillator (ICD), when using service, etc, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of TCU might affect function, pRECAUTION AT INTELLIGENT KEY SYSTEM OPERATION.
The electromagnetic wave of Intelligent Key might affect the function implantable cardiac, pacemaker or the implantable cardioverter defibrillator (ICD), at door operation, each request, if a technician uses other medical electric devices than implantable cardiac pacemaker implant- M, able cardioverter defibrillator (ICD), the electromagnetic wave of Intelligent Key might affect.
Point to Be Checked Before Starting Maintenance Work, the high voltage system may starts automatically, and timer charge (during EVSE connection) are not set before starting maintenance work, if the timer air conditioner or timer charge (during EVSE connection) is set, the high voltage system starts.
Automatically even when the power switch OFF state, precaution for Supplemental Restraint System (SRS) "AIR BAG" "SEAT BELT, the Supplemental Restraint System such as AIR BAG” and SEAT BELT PRE-TENSIONER”, used along.