Download Heater & Air Condition (Section HA)
Manual DescriptionPrecaution for Technicians Using Medical Electric 3, point to Be Checked Before Starting Maintenance, precautions for Removing Battery Terminal 6, (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER" 6.
Precaution for Procedure without Cowl Top Cover 7, precautions for Service Work Cooler System 7, dIAGNOSIS AND REPAIR WORK FLOW 29, hEATING SYSTEM : Component Parts Location 19.
A/C UNIT ASSEMBLY : A/C Unit 20, a/C UNIT ASSEMBLY : Evaporator 20, a/C UNIT ASSEMBLY : Expansion Valve 20, a/C UNIT ASSEMBLY : Heater Core 20.
Trouble Diagnosis For Unusual Pressure 40, cONDENSER : Removal Installation 56, lIQUID TANK : Removal Installation 58, rEFRIGERANT PRESSURE SENSOR : Removal Installation 59.
A/C UNIT ASSEMBLY : Removal Installation 62, eVAPORATOR : Removal Installation 64, hEATER CORE : Removal Installation 65, hIGH-PRESSURE PIPE : Removal Installation 54.
Precaution for Technicians Using Medical Electric, parts with strong magnet is used vehicle, technicians using a medical electric device such as pacemaker must never perform operation, vehicle, as magnetic field can affect the device function by approaching such parts.
If a technician uses a medical electric device such as an implantable cardiac pacemaker an, implantable cardioverter defibrillator, the possible effects on the devices must be checked with, device manufacturer before starting charge operation, as radiated electromagnetic wave generated by on board charger at normal charge operation may.
Effect medical electric devices, a technician using a medical electric device such as implantable cardiac pacemaker or an implantable cardioverter defibrillator must not enter vehicle compartment, (including luggage room) during normal charge operation, if a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), H, avoid the device implanted part from approaching within approximately 220 mm (8.
The electromagnetic wave of TCU might affect the function of the implantable cardiac pacemaker, the implantable cardioverter defibrillator (ICD), when using service, etc, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of TCU might affect function, pRECAUTION AT INTELLIGENT KEY SYSTEM OPERATION.
If a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of Intelligent Key might affect the function implantable cardiac, pacemaker or the implantable cardioverter defibrillator (ICD), at door operation, each request, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of Intelligent Key might affect.
Since hybrid vehicles and electric vehicles contain a high voltage battery, there risk, electric shock, electric leakage, or similar accidents if the high voltage component vehicle, be sure to remove the service plug in order to disconnect the high voltage circuits before performing inspection or maintenance of high voltage system harnesses parts, the removed service plug must always be carried in a pocket of the responsible worker placed.
The tool box during the procedure to prevent the plug from being connected by mistake, be sure to wear insulated protective equipment before beginning work on high voltage system, never allow workers other than the responsible person to touch the vehicle containing high voltage, never bring the vehicle into the READY status with the service plug removed unless otherwise.
HIGH VOLTAGE HARNESS AND EQUIPMENT IDENTIFICATION, all the high voltage harnesses and connectors are orange, include an orange high voltage label, hANDLING OF HIGH VOLTAGE HARNESS AND TERMINALS.
Immediately insulate disconnected high voltage connectors and terminals with insulating tape, rEGULATIONS ON WORKERS WITH MEDICAL ELECTRONICS, the vehicle contains parts that contain powerful magnets.