Download Brake System (Section BR)
Manual DescriptionPrecaution for Technicians Using Medical Electric 4, point to Be Checked Before Starting Maintenance, (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER" 4, precautions for Removing Battery Terminal 5.
Precaution for Procedure without Cowl Top Cover 6, dIAGNOSIS AND REPAIR WORK FLOW 31, sTROKE SENSOR POINT LEARNING 35, brake Power Supply Backup Unit 12.
DIAGNOSIS SYSTEM (ELECTRICALLYDRIVEN INTELLIGENT BRAKE UNIT)21, pOWER SUPPLY AND GROUND CIRCUIT 221, tHE BRAKING DISTANCE IS LONG 230, bRAKE PAD : Inspection Adjustment 244.
DISC ROTOR : Inspection Adjustment 244, bRAKE PAD : Inspection Adjustment 246, dISC ROTOR : Inspection Adjustment 246, fRONT : Removal Installation 252.
REAR : Removal Installation 255, bRAKE PAD : Exploded View 263, bRAKE PAD : Removal Installation 263, bRAKE CALIPER ASSEMBLY : Exploded View 265.
BRAKE CALIPER ASSEMBLY : Removal Installation 266, bRAKE CALIPER ASSEMBLY : Disassembly, bRAKE CALIPER ASSEMBLY : Inspection 270, bRAKE PAD : Exploded View 271.
BRAKE PAD : Removal Installation 271, bRAKE CALIPER ASSEMBLY : Exploded View 273, bRAKE CALIPER ASSEMBLY : Removal Installation 275, bRAKE CALIPER ASSEMBLY : Inspection 278.
BRAKE POWER SUPPLY BACKUP UNIT 261, precaution for Technicians Using Medical Electric, parts with strong magnet is used vehicle, technicians using a medical electric device such as pacemaker must never perform operation.
Vehicle, as magnetic field can affect the device function by approaching such parts, if a technician uses a medical electric device such as an implantable cardiac pacemaker an, implantable cardioverter defibrillator, the possible effects on the devices must be checked with, device manufacturer before starting charge operation.
As radiated electromagnetic wave generated by on board charger at normal charge operation may, effect medical electric devices, a technician using a medical electric device such as implantable cardiac pacemaker or an implantable cardioverter defibrillator must not enter vehicle compartment, (including luggage room) during normal charge operation, if a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD).
Avoid the device implanted part from approaching within approximately 220 mm (8, the electromagnetic wave of TCU might affect the function of the implantable cardiac pacemaker, the implantable cardioverter defibrillator (ICD), when using service, etc, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of TCU might affect function.
PRECAUTION AT INTELLIGENT KEY SYSTEM OPERATION, the electromagnetic wave of Intelligent Key might affect the function implantable cardiac, pacemaker or the implantable cardioverter defibrillator (ICD), at door operation, each request, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of Intelligent Key might affect.
Point to Be Checked Before Starting Maintenance Work, the high voltage system may starts automatically, and timer charge (during EVSE connection) are not set before starting maintenance work, if the timer air conditioner or timer charge (during EVSE connection) is set, the high voltage system starts.
Automatically even when the power switch OFF state, precaution for Supplemental Restraint System (SRS) "AIR BAG" "SEAT BELT, the Supplemental Restraint System such as AIR BAG” and SEAT BELT PRE-TENSIONER”, used along.