Download Road Wheels & Tires (Section WT)
Manual DescriptionPrecaution for Technicians Using Medical Electric 3, point to Be Checked Before Starting Maintenance, (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER" 3, service Notice and Precautions TPMS 4.
Service Notice and Precautions Road Wheel 4, dIAGNOSIS AND REPAIR WORK FLOW 20, tIRE PRESSURE SENSOR ID REGISTRATION 23, cOMMON ITEM : CONSULT Function (BCM COMMON ITEM) 12.
AIR PRESSURE MONITOR : CONSULT Function, (BCM - AIR PRESSURE MONITOR) 14, c1711 TIRE PRESSURE SENSOR 27, c1719 TIRE PRESSURE SENSOR 29.
POWER SUPPLY AND GROUND CIRCUIT 32, tIRE PRESSURE SENSOR ID REGISTRATION CANNOT BE COMPLETED 40, how to Handle Puncture Repair Agent 45, precaution for Technicians Using Medical Electric.
Parts with strong magnet is used vehicle, technicians using a medical electric device such as pacemaker must never perform operation, vehicle, as magnetic field can affect the device function by approaching such parts, if a technician uses a medical electric device such as an implantable cardiac pacemaker an WT.
Implantable cardioverter defibrillator, the possible effects on the devices must be checked with, device manufacturer before starting charge operation, as radiated electromagnetic wave generated by on board charger at normal charge operation may, effect medical electric devices, a technician using a medical electric device such as implantable cardiac pacemaker or an implantable cardioverter defibrillator must not enter vehicle compartment.
(including luggage room) during normal charge operation, if a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), avoid the device implanted part from approaching within approximately 220 mm (8, the electromagnetic wave of TCU might affect the function of the implantable cardiac pacemaker.
The implantable cardioverter defibrillator (ICD), when using service, etc, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator(ICD), the electromagnetic wave of TCU might affect function, precaution at intelligent key system operation, the electromagnetic wave of intelligent key might affect the function implantable cardiac.
Pacemaker or the implantable cardioverter defibrillator (ICD), at door operation, each request, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of intelligent key might affect the function of the device, point to Be Checked Before Starting Maintenance Work, precaution for Supplemental Restraint System (SRS) "AIR BAG" "SEAT BELT.
The Supplemental Restraint System such as AIR BAG” and SEAT BELT PRE-TENSIONER”, used along, with a front seat belt, helps to reduce the risk or severity of injury to the driver and front passenger certain, the high voltage system may starts automatically, and timer charge (during EVSE connection) are not set before starting maintenance work.
If the timer air conditioner or timer charge (during EVSE connection) is set, the high voltage system starts, automatically even when the power switch OFF state, system uses the seat belt switches to determine the front air bag deployment, and may only deploy one front, air bag, depending on the severity of a collision and whether the front occupants belted unbelted.
Information necessary to service the system safely is included in the SRS AIR BAG” and SEAT BELT”, always observe the following items preventing accidental activation, to avoid rendering the SRS inoperative, which could increase the risk of personal injury death, the event of a collision that would result in air bag inflation, all maintenance must be performed by.
Improper maintenance, including incorrect removal and installation of the SRS, can lead personal, injury caused by unintentional activation of the system, never use electrical test equipment on any circuit related to the SRS unless instructed to in this Service Manual, pRECAUTIONS WHEN USING POWER TOOLS (AIR OR ELECTRIC) AND HAMMERS.
When working near the Air Bag Diagnosis Sensor Unit or other Air Bag System sensors with, power switch ON, never use air or electric power tools or strike near the sensor(s) with hammer, heavy vibration could activate the sensor(s) and deploy the air bag(s), possibly causing serious.